• Home
  • Electrostatic
  • Air Technology
  • Cleaning Technology
  • Customized
  • Company
  • Contact
Ziegener + Frick
  • Overview
  •   |  
  • Cleaning systems
  •   |  
  • Cleaning with copmressed air
  •   |  
  • Cleaning with air Blowing
  •   |  
  • Cleaning in Ex(plosive) - range
  •   |  
  • Customized
ziegner-frick.com› Cleaning Technology› Cleaning in Ex(plosive) - range› LLR 6045 with P-SH-N-EX

Cleaning in Ex(plosive) - range

  • LLR 6045 with P-SH-N-EX
  • Typhoon with P-SH-N EX
Airduct-Tube-LLR-6045-with-Antistatic-Bar-P-SH-N-EX
Logo
Airduct-Tube-LLR-6045-with-Antistatic-Bar-P-SH-N-EX

LLR 6045 with P-SH-N-EX

  • General
  • Detail
  • Technical Data
  • Downloads

The combination of an airduct tube 6045 and a contact proof antistatic bar can be supplied in nearly all requested lengths and air volumes. The compressed air is blown out of nozzles over the full length across to the high voltage spike at an angle of 45°.

According to installation situation and air volume, the accordant airduct tube is chosen.

P-SH-N-EX Antistatic bar

Function:

The positive and negative ions generated by the antistatic bar saturate the airflow coming out of the nozzles. This airflow transports the ions onto the product to be neutralized. The electrostatic charges on the product will be eliminated and depending on air pressure adherent contamination will be blown away.

Application:

Neutralization over wide distances Powerful cleaning.

Specifications LLR 6045
Dimensions 45 x 60 mm (W x H) incl. nozzle H = 78 mm
Active length in the pattern 19,05 mm to 6000 mm
Nozzles D=1,6 mm² Pattern 90 mm
Antistatic bar P-SH-N-EX
Working direction 45° across to high voltage spike
Accreditation CE, ATEX
Befestigung on the backside, slot nut M8. The antistatic bar is fixed at the airduct tube with brackets.
Approx. air consumption / noise level per nozzle
Pressure in bar 1,0 bar 2,0 bar 3,0 bar 4,0 bar 5,0 bar 6,0 bar 7,0 bar
Measuring distance noise-level              
500 mm 80 dBA 81 dBA 83 dBA 85 dBA 87 dBA 88 dBA 90 dBA
1000 mm 75 dBA 76 dBA 78 dBA 79 dBA 81 dBA 82 dBA 84 dBA
1500 mm 72 dBA 74 dBA 75 dBA 77 dBA 79 dBA 80 dBA 81 dBA
               
Air consumption 44 NL/min 64 NL/min 87 NL/min 105 NL/min 140 NL/min 155 NL/min 180 NL/min

Download

LLR_PSHNEX_6045_Operatingmanual_de 380 KB
LLR_PSHNEX_6045_Drawing 130 KB
PSHNEX_Operatingmanual_en 431 KB
  • Imprint
  • Terms and Conditions
  • Data privacy
  • Sitemap
Copyright © 2010 Ziegener + Frick GmbH   |    Design by www.hela.com   |    LinkedIn Xing YouTube